Specifications

Analog TV
Configured as R&S® NH8602C NH8603C NH8604C NH8605C NH8606C NH8608C NH8610C NH8612C NH8616C NH8620C
Number of R&S®VH8600A1
amplifiers
2 3 4 5 6 8 10 12 16 20
Output power
(sync peak) 1)
3.5 kW 5.1 kW 7.0 kW 8.5 kW 10 kW 13.3 kW 16.3 kW 19.5 kW 25.6 kW 31.4 kW
RF output EIA 1 5/8" EIA 3 1/8" EIA 4 1/2"
Dimensions
(H × W × D)
2000 mm × 600 mm × 1100 mm
(78.7 in × 23.6 in × 43.3 in)
2000 mm × 1200  mm ×  1100  mm
(78.7 in × 47.2 in × 43.3  in)

1) After four-cavity bandpass filter; other output powers on request.

 

Specifications
Digital TV
TV standards   DVB-T, DVB-T2, DVB-H, ISDB-T, ISDB-TB, DTMB, MediaFLO, ATSC, ATSC Mobile DTV,
Inputs   4 × BNC, 75 Ω
  DVB-T2 2 × BNC, 75 Ω and 2 × RJ-45
Analog TV
TV standards   B/G, D/K, M, M1, N, I, I1
Color transmission   PAL, NTSC, SECAM
Sound transmission   dual-sound coding in line with IRT or FM single sound and NICAM728
(−13  dB/−20  dB) or
FM single sound (−10 dB)
Inputs   2 × video (BNC, 75 Ω), 2 × audio
(XLR, 3-contact)
General data
Frequency range UHF bands IV/V 470 MHz to 862 MHz
Power supply with three-phase amplifiers (standard) 3 × 400 V ± 15 % 1),
47 Hz to 63 Hz
with single-phase amplifiers (optional, for R&S®NV8602 to R&S®NV8610) 3 × 208 V – 10 %/+ 15 % 1) or
240 V – 15 %/+ 10 % 2)
47 Hz to 63 Hz
Max. installation altitude   2000 m above sea level
(> 2000  m on request)
Operating temperature range   +1 °C to +45 °C
Relative humidity (max.)   95 %, non-condensing
Immunity 3) to fast transients and burst in line with IEC  61000-4-4 < 4 kV (AC supply),
< 1 kV (signal inputs)
to surges in line with
IEC  61000-4-5
balanced < 2 kV (e.g. L1-L2)
unbalanced < 4 kV (e.g. L1-N)
Synchronization
Reference frequency   10 MHz, 0.1 V to 5 V (Vpp) or TTL, BNC
Reference pulse   1 Hz, TTL, BNC
Operation
Display, keypad and status LEDs   local operation and display
Ethernet interface, RJ-45   convenient operation, local or remote, via standard web browser
optional network management interface via SNMP
Parallel remote-control interface optional floating contacts for messages and commands
1) To be connected to an AC supply network with Y, 3w + N + PE.
2) To be connected to an AC supply network with 120/240 V, 2w + N + PE.
3) With integrated AC supply overvoltage protection; more stringent requirements must be covered by additional on-site measures.

To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.