R&S®NM8500 VHF Transmitter Family for TV

Flexible and efficient: a platform for the future

Specifications

Analog TV
Configured as R&S® NM8503 NM8504 NM8508 NM8516
Number of R&S®VM602A1 amplifiers 3 4 8 16
Output power (sync peak) 1) 2) 4.0 kW 5.0 kW 10.0 kW 20.0 kW
RF output EIA 1 5/8" EIA 3 1/8"
Dimension
(H x W x D)
2200 mm x 600 mm x 1200 mm
(86.6 in x 23.6 in x 47.2 in)
2200 mm x 1200 mm x 1200 mm
(86.6 in x 47.2 in x 47.2 in)

1) Other output power ratings on request.
2) After the bandpass filter.

Base unit
Frequency range VHF band III 170 MHz to 254 MHz
Supply voltage   3 x 400 V AC ± 15%, 47 Hz to 63 Hz
three-phase current
Max. installation height   2000 m above sea level
(> 2000 m on request)
Operating temperature range   +1°C to +45°C
Relative humidity (max.)   95%, non-condensing
Immunity1) to fast transients and burst in line with IEC61000-4-4 < 4 kV (AC supply)
< 1 kV (signal inputs)
  to surges in line with IEC61000-4-5 symmetrical < 2 kV (e.g. L1-L2)
unsymmetrical < 4 kV (e.g. L1-N)
Synchronization
Reference frequency   10 MHz, 0.1 V to 5 V (VPP) or TTL, BNC
Reference pulse   1 Hz, TTL, BNC
Operation
Display, keypad and status LEDs   local operation and display
Ethernet interface, RJ-45   convenient operation, local or remote,
via standard web browser
  optional network management interface via SNMP
Parallel remote-control interface optional floating contacts for messages and commands
Analog TV
TV standards   B/G, D/K, M, M1, N, I, I1
Color transmission   PAL, NTSC, SECAM
Audio transmission   dual-sound coding in line with IRT or FM single sound and NICAM728
(-13 dB/-20 dB) or FM single sound (-10 dB)
Inputs   2 x video (BNC, 75 Ω), 2 x audio (XLR, 3-pin)

1) With built-in AC supply overvoltage protection; more stringent requirements must be covered by additional measures installed on-site.

To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.