R&S®NW8500 VHF Transmitter Family for TV

Flexible and efficient: a platform for the future

Specifications

Digital TV
Configured as R&S® NW8502 NW8503 NW8504 NW8505 NW8506 NW8508 NW8510 NW8512 NW8516
Number of R&S®VM602A1 amplifiers 2 3 4 5 6 8 10 12 16
Output power (RMS) for COFDM standards 1) 2) 1.0 kW 1.5 kW 2.0 kW 2.5 kW 3.0 kW 4.0 kW 4.8 kW 5.8 kW 7.8 kW
Output power (RMS) for ATSC/ATSC Mobile DTV 1) 2) 1.5 kW 2.2 kW 2.9 kW 3.7 kW 4.4 kW 5.8 kW 7.2 kW 8.8 kW 11.5 kW
RF output EIA 1 5/8" EIA 3 1/8"
Dimension
(H x W x D)
2200 mm x 600 mm x 1200 mm
(86.6 in x 23.6 in x 47.2 in)
2200 mm x 1200 mm x 1200 mm
(86.6 in x 47.2 in x 47.2 in)

1) Other output power ratings on request.
2) Before the bandpass filter.

Base unit
Frequency range VHF band III 170 MHz to 254 MHz
Supply voltage   3 x 400 V AC ± 15%, 47 Hz to 63 Hz
three-phase current
Max. installation height   2000 m above sea level
(> 2000 m on request)
Operating temperature range   +1°C to +45°C
Relative humidity (max.)   95%, non-condensing
Immunity1) to fast transients and burst in line with IEC61000-4-4 < 4 kV (AC supply)
< 1 kV (signal inputs)
  to surges in line with IEC61000-4-5 symmetrical < 2 kV (e.g. L1-L2)
unsymmetrical < 4 kV (e.g. L1-N)
Synchronization
Reference frequency   10 MHz, 0.1 V to 5 V (VPP) or TTL, BNC
Reference pulse   1 Hz, TTL, BNC
Operation
Display, keypad and status LEDs   local operation and display
Ethernet interface, RJ-45   convenient operation, local or remote,
via standard web browser
  optional network management interface via SNMP
Parallel remote-control interface optional floating contacts for messages and commands
Digital TV
TV standard   DVB-T, DVB-T2, DVB-H, ISDB-T, ISDB-TB, DTMB, MediaFLO, ATSC, ATSC Mobile DTV
Inputs DVB-T, DVB-H, ISDB-T, ISDB-TB, DTMB, MediaFLO, ATSC, ATSC Mobile DTV 4 x BNC, 75Ω
  DVB-T2 2 x BNC, 75Ω and RJ-45

1) With built-in AC supply overvoltage protection; more stringent requirements must be covered by additional measures installed on-site.

To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.