R&S®SLx8000A UHF/VHF Transmitter
Low-power transmitter for analog TV
Specifications
| Transmitters with 2 HU |
Transmitters with 3 HU |
Transmitters with 4 HU |
|
|---|---|---|---|
| Frequency range UHF (band IV/V) | 470 MHz to 862 MHz | – | |
| Frequency range VHF (band III) | – | 174 MHz to 240 MHz | |
| Available standards | |||
| Analog TV | B/G, D/K, I, L, M, N | – | |
| Digital TV | DVB-T, DVB-T2, DVB-H, ISDB-T, ISDB-TB, ATSC, ATSC Mobile DTV | – | |
| Digital audio broadcasting | – | DAB, DAB+, T-DMB | |
| Supported network types | MFN, SFN (only for digital TV and digital audio broadcasting) | ||
| Supply voltage | 100 V to 240 V AC, ±10% | 230 V, -10% to +15% | |
| Supported AC frequencies | 50 Hz, 60 Hz | ||
| Option | -48 V DC | – | |
| Synchronization | |||
| Reference frequency | 10 MHz, 0.1 V to 5 V (VPP) or TTL, BNC | ||
| Reference pulse | 1 pps (1 Hz, TTL, BNC) | ||
| Operation | |||
| Local control | display, keypad and status LEDs, web interface (via Ethernet port) | ||
| Remote-control interfaces | web interface (via Ethernet port) and SNMP (option), floating contacts (option) | ||
| Environmental conditions | |||
| Max. installation height | 2000 m above sea level (> 2000 m on request) | ||
| Operating temperature range | +1 °C to +45 °C | ||
| Relative humidity (max.) | 95%, non-condensing | ||
| Immunity | class 2 (B) immunity to fast transients and burst in line with IEC61000-4-4: < 2 kV (power supply) and < 1 kV (signal inputs); class 3 (C) immunity to surges in line with IEC61000-4-5: •symmetrical < 1 kV (e.g. L1-L2) •unsymmetrical < 2 kV (e.g. L1-N) If the transmitter is operated in another class (>2 or 3), protective measures must be taken. Rohde & Schwarz offers options for overvoltage and lightning protection. |
||
| Dimensions (W x H x D) |
483 mm (19") x 88 mm x 467 mm (19.02 in x 3.46 in x 18.39 in) |
483 mm (19") x 132 mm x 474 mm (19.02 in x 5.2 in x 18.66 in) |
483 mm (19") x 176 mm x 590 mm (19.02 in x 6.93 in x 23.23 in) |
| Remark | To comply with the applicable standards and limit values for the suppression of out-of-brand emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output. | ||