R&S®TS6030 I-Level Special Test Equipment
Fast and easy on-site maintenance of radios, amplifiers and control units
Specifications
| General Data | ||
|---|---|---|
| Dimensions | ||
| Basic system rack/EPM (ECCM) mode extension | with cover (W × H × D) | 534 mm × 618 mm × 710 mm (21.02 in × 24.33 in × 27.99 in) |
| without cover (W × H × D) | 534 mm × 618 mm × 580 mm (21.02 in × 24.33 in × 22.83 in) | |
| Weight | basic system rack | 75 kg (165.35 lb) |
| EPM (ECCM) mode extension | 50 kg (110.23 lb) | |
| Temperature range | operating | +5 °C to +40 °C |
| storage | –20 °C to +60 °C | |
| best test accuracy | +20 °C to +23 °C | |
| damp heat | +40 °C at 95 % relative humidity | |
| Power supply | 100 V AC to 240 V AC, 50/60 Hz | |
| Fuse protection | 115 V | 16 A |
| 230 V | 10 A | |
| Time required | ||
| Connecting a UUT | <5 min | |
| Complete test | <30 min (depending on type and equipment) | |
| <30 min (depending on type and equipment) | ||
| approx. 40 min (depending on type and equipment) | ||
| Test system setup | <30 min | |
| Test system dismantling | <30 min | |
| Recommended calibration cycle | 1 year | |