Specifications
| General data | ||
|---|---|---|
| Air interface specification | in line with EN 300 392-2 (TETRA V+D) | |
| Air interface testing | in line with EN 300 394-1, V 2.3.1 | |
| Frequency range | 380 MHz to 470 MHz | |
| others on request | ||
| Frequency step | 6.25 kHz | |
| Carrier spacing, hybrid combiner | ≥ 50 kHz | |
| Duplex spacing | at ≤ 470 MHz | ≥ 10 MHz (others on request) |
| Operating mode | duplex | |
| Synchronization | GPS | |
| Output power | ||
| Transmitter output | nom. 47 dBm | |
| TOC (TX/RX female antenna connector) | without transmitter coupling | nom. 44 dBm |
| With hybrid coupler | 2 carriers | nom. 41 dBm |
| Static sensitivity, TOC | without diversity (TCH7.2, BER 4 %) | better than -119 dBm |
| Dynamic sensitivity, TOC | without diversity | |
| TU 50 (TCH7.2, BER 4 %) | better than -113 dBm | |
| in line with EN 300 392-2, class A | better than -108 dBm | |
| in line with EN 300 392-2, class B | better than -110 dBm | |
| Receiver diversity | 2x (with equipped diversity receive path) | |
| Power consumption | with one carrier with 47 dBm transmit power | 350 W |
| with two carriers, each with a transmit power of 47 dBm | 550 W | |
| Power supply | AC | nom. 240 V |
| DC | nom. 48 V, optional | |
| Dimensions | W x H x D | 600 mm x 910 mm x 600 mm (23.6 in x 35.8 in x 23.6 in) |
| Weight | approx. 90 kg (198.4 lb) | |