Discontinued Product

Please note the following successor product(s):

R&S®UPL Audio Analyzer

Compact instrument for audio measurements at analog and digital interfaces

Application Notes

1GA12: External Sweep and Adaptive Measurement of DUTs with extreme Transients using the Settling Function of the Audio Analyzers UPL and UPD

Abstract
When measuring audio components with unknown transients, the experienced engineer watches the settling of the DUT before accepting a measured result to be valid. The settling function in the UPL/UPD simulates this process and automates it by continuously comparing the measured value with a number of measured values stored before. A measured value is only accepted as being valid if it is within the tolerance limits entered by the user. This application note explains the settling process and gives hints for practical use.
Last Modified
03.06.1998
File NameVersionLast ModifiedFile Size
1GA12_1L.pdf
Application Note - English version
1   17.04.1998   0.5 MB
1GA12_1D.pdf
Application Note - German version
1   03.06.1998   0.4 MB