R&S®EMC32-K3 R&S®EMC32-S option for EMS measurements in Mode Tuned Chambers "Reverberation Chamber"
requires R&S®EMC32-K4 option
Key Facts
The Option concept of R&S EMC32-S version 6.0 allows functionality extensions according to the specific customer needs.For previous versions of EMC32-S please order the EMC32-U6 Upgrade package.
The option allows measurements according to the standards EN61000-4-21, GMW3097 Feb. 2004 and ES-XW7T-1A278-AC. It supports the complete measurement procedure including calibration of the reverb chamber (loaded and unloaded), DUT check and DUT test.