R&S®ENV216 Two-Line V-Network
For disturbance voltage measurements on single-phase EUTs
Specifications
| Frequency range | 9 kHz to 30 MHz | ||
| Simulated impedance | phase and magnitude | (50 µH + 5 Ω) || 50 Ω | |
| Error limits | in line with CISPR 16-1-2 | ±20% (magnitude), ±11.5° (phase) | |
| Isolation 1) | 9 kHz to 50 kHz | >0 dB to 40 dB (increases linearly with logarithm of frequency) | |
| 50 kHz to 30 MHz | >40 dB | ||
| AC supply voltage | If the EUT is operated with AC voltages up to 90 V and DC voltages up to 50 V, the logic circuit has to be powered via the external plug-in power supply that is supplied as standard. | 0 V to 240 V AC + 10% | |
| AC supply frequency | 50 Hz to 60 Hz ± 5% | ||
| DC voltage | 0 V to 50 V DC | ||
| Maximum permissible continuous current | country-specific | ||
| Model 12 | 16 A | ||
| Model 13 | 13 A | ||
| Model 14 | 16 A | ||
| Model 15 | 10 A | ||
| Model 16 | 15 A | ||
| Maximum permissible RF disturbance power from EUT | 1 W | ||
| Highpass filter | integrated, switch-selectable | 150 kHz | |
| Voltage division factor between EUT and measuring receiver port | built-in attenuator pad, calibration data supplied with V-network | 10 dB | |
| Response threshold of built-in pulse limiter | can be switched off | 140 dB (µV) | |
| Connectors | |||
| AC supply input | country-specific | plug with protective earth contact and 1.8 m cable | |
| AC supply voltage input for EUT | country-specific | socket with protective earth contact | |
| RF output | N female, 50 Ω | ||
| Remote control input | 25-contact, D-Sub, female | ||
| Input for artificial hand | 4 mm connector, female, with knurled clamp | ||
| Reference ground connection | ground bar with three M4 threads | ||
| Protective earth connection | M6 threaded bolt | ||
| Connector for external power supply | on rear panel, by supplied plug-in power supply | DC hollow connector Ø5.5 mm, 2.1 mm, 10 V to 18 V DC, 250 mA | |
1) Between AC supply and measuring receiver port.