Specifications

R&S®ENV216 two-line V-network
Frequency range   9 kHz to 30 MHz
Simulated impedance phase and magnitude (50 µH + 5 Ω) || 50 Ω
  Error limits in line with CISPR 16-1-2 ±20% (magnitude), ±11.5° (phase)
Isolation 1) 9 kHz to 50 kHz  >0 dB to 40 dB (increases linearly with logarithm of frequency)
50 kHz to 30 MHz  >40 dB
Test path to EUT
AC supply voltage If the EUT is operated with AC voltages up to 90 V and DC voltages up to 50 V, the logic circuit has to be powered via the external plug-in power supply that is supplied as standard. 0 V to 240 V AC + 10%
AC supply frequency   50 Hz to 60 Hz ± 5%
DC voltage   0 V to 50 V DC
Maximum permissible continuous current country-specific  
  Model 12   16 A
  Model 13   13 A
  Model 14   16 A
  Model 15   10 A
  Model 16   15 A
Test path to measuring receiver
Maximum permissible RF disturbance power from EUT   1 W
Highpass filter integrated, switch-selectable 150 kHz
Voltage division factor between EUT and measuring receiver port built-in attenuator pad, calibration data supplied with V-network 10 dB
Response threshold of built-in pulse limiter can be switched off 140 dB (µV)
Connectors
AC supply input country-specific plug with protective earth contact and 1.8 m cable
AC supply voltage input for EUT country-specific socket with protective earth contact
RF output   N female, 50 Ω
Remote control input   25-contact, D-Sub, female
Input for artificial hand   4 mm connector, female, with knurled clamp
Reference ground connection   ground bar with three M4 threads
Protective earth connection   M6 threaded bolt
Connector for external power supply on rear panel, by supplied plug-in power supply DC hollow connector Ø5.5 mm, 2.1 mm, 10 V to 18 V DC, 250 mA

1) Between AC supply and measuring receiver port.