R&S®ENY81-CA6 Coupling Network

For radio disturbance and immunity measurements on telecommunications ports

Specifications

Specifications
Frequency range
Radio disturbance measurements   150 kHz to 30 MHz
Immunity measurements   150 kHz to 80 MHz
Asymmetrical impedance
Impedance 0.15 MHz to 30 MHz 150 Ω ± 20 Ω
  >30 MHz to 80 MHz 150 Ω ± 40 Ω
Phase angle 0.15 MHz to 30 MHz 0° ± 20°
Voltage division factor in asymmetrical circuit
150 kHz to 30 MHz calibration data supplied 1) typ. 9.5 dB ± 1 dB
>30 MHz to 80 MHz   typ. 9.5 dB ± 2 dB
Transmission bandwidth (3 dB) typ. for 100 Ω source and
load impedance
>250 MHz
Longitudinal conversion loss (LCL)
LCL (dB)   75 – 10 log (1+(f/5)2) dB
Tolerance for f < 2 MHz ±3 dB
  for 2 MHz ≤f ≤30 MHz –3 dB/+6 dB
Decoupling attenuation
150 kHz to 1.5 MHz linear increase with logarithmic frequency >35 dB to 55  dB
1.5 MHz to 30 MHz   >55 dB
Crosstalk (PSELFEXT, EUT/AE)
1 MHz to 250 MHz linear decrease with logarithmic frequency ≥61 dB to ≥15 dB
Power-handling capacity
Max. permissible RF input voltage   15 V
Max. permissible DC voltage between line and ground   100 V
Max. permissible AC voltage between line and ground   63 V
Max. permissible DC current forward and reverse current on one wire pair or multiple wire pairs 400 mA
Connectors
Output to test receiver/input from signal
generator
  BNC female
Connectors for EUT and AE   RJ-45 female
General data
Operating temperature range   +5 °C to +40 °C
Storage temperature range   –20 °C to +70 °C
Dimensions, base unit W × H × D 105 mm × 65 mm × 110 mm
(4.13 in × 2.26 in × 4.33 in)
Weight
  Base unit   500 g (1.1 lb)
  Carrying case with base unit   1900 g (4.2 lb)

1)The calibration data includes asymmetrical impedance and phase, voltage division factor, decoupling attenuation, longitudinal conversion loss (LCL), transmission bandwidth and crosstalk.