Specifications

Data interfaces
DIGITAL IQ IN/OUT
(R&S®Digital I/Q Interface)
no simultaneous data transfer 1 x I/Q input, 1 x I/Q output
  input clock rate 66 MHz to 100 MHz
  output clock rate 100 MHz
I/O 1 to I/O 8 trigger signals 8 × BNC sockets for I/O signals including max. two for trigger signals
  programmable I/O signals (future release) 2 x 4 programmable I/O
Reference clock input socket, BNC
output socket, BNC
10 MHz
10 MHz
I/Q data
I/Q word size   16 bit per channel
Sample rate R&S®IQR20 1 ksample/s to 20 Msample/s
  R&S®IQR100 1 ksample/s to 66 Msample/s 1)
Data rate R&S®IQR20 up to 80 Mbyte/s
  R&S®IQR100 up to 270 Mbyte/s 1)
General data
Power supply exchangeable 100 V to 240 V AC (±10 %), 160 VA,
50 Hz to 60 Hz/400 Hz (±5 %)
Mechanical resistance vibration, random  
  R&S®IQR20, R&S®IQR100 in operating mode with integrated system memory and SSD memory pack (R&S®IQR-B1xx) in line with EN 60068-2-64
10 Hz to 300 Hz, acceleration 1.9 g (RMS),
300 Hz to 500 Hz, acceleration 1.2 g (RMS)
  R&S®IQR20 in operating mode with HDD memory pack (R&S®IQR-B0xx) limited by the HDD memory pack (ideal for stationary use) 2)
Environmental conditions operating temperature range 0°C to +50°C
  storage temperature range –20°C to +70°C
  damp heat +40°C, 85 % rel. humidity, cyclic test in line with EN 60068-2-30
Dimensions W × H × D, overall 249 mm × 150 mm × 401 mm
(9.82 in × 5.91 in × 15.79 in)
  for 19" rack mounting ½ 19", 3 HU, depth 350 mm (13.78 in)
Weight   approx. 6.6 kg (20.94 lb)
1) Depending on the memory pack used.
2) No values specified by the manufacturer of the HDD.