R&S®R-Line Compact Test Chamber

Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

Specifications

General data

Environmental conditions    
Operating temperature range   +0°C to +35°C
Storage temperature range   –10°C to +45°C
Relative humidity without condensation 90 % at +40 °C, non-condensing
Power supply 208 V to 230 V/50 Hz to 60 Hz max. 350 VA
Environmental test    
Electromagnetic compatibility EU – EMC Directive 2004/108/EC in line with EN 61326-1, EN 55011 (class B),
EN 61000-3-2, EN 61000-3-3
Electrical safety EU – Low Voltage Directive 2006/95/EC in line with EN 61010-1
Mechanical data    
Dimensions (W × H × D) including four movable and lockable castors 1700 mm × 2250 mm × 1640 mm
(66.93 in × 88.58 in × 64.57 in)
Weight   562 kg (1239 lb)
Door size (W × H)   500 mm × 1000 mm
19.68 in × 39.37 in
Size of EUT (∅ × H)   max. 330 mm × 240 mm
max. 12.99 in × 9.45 in
Weight of EUT   max. 1 kg (max. 2.2 lb)
Positioning speed of turntable   azimuth: 0.5 rpm to 10 rpm
elevation: 0.2 rpm to 10 rpm
Distance between test antenna and center of EUT    1.03 m (40.55 in)
Interfaces Data  
IEC/IEEE bus, RS-232-C alternatively for control of positioner in line with IEC 625-2 (IEEE 488.2)
Test antenna   2 × SMA (female)
Communications antenna   1 × N (female)
RF feedthroughs for calibration or connecting the EUT 2 × N (female)
2 × SMA (female)

RF specifications

Measurement range    
Frequency range   800 MHz to 18 GHz
Polarization   horizontal and vertical, through ¸R&S®HL024A1 cross-polarized antenna
RF power   max. 3 W
Communications antenna   800 MHz to 6 GHz, circularly polarized
Field uniformity site VSWR, typ. 2 dB in line with CISPR 16-1-4:2007
Shielding effectiveness > 95 dB 800 MHz to 6 GHz
> 70 dB 6 GHz to 18 GHz