| Common data | ||
| Overall frequency range | depending on specific device configuration | 400 MHz to 6.0 GHz or 400 MHz to 3 GHz |
| Maximum DUT cable loss | 3,5 dB (6 GHz) | |
| DUT TX/RX 1 and DUT TX/RX 2 | max. RF output power | ≥–25 dBm RMS |
| max. DUT input power | +26 dBm | |
| max. input DC level | 0 V DC | |
| nominal source impedance | 50 Ω | |
| max. VSWR, 400 MHz ≤ f <3 GHz | 1.2:1 | |
| max. VSWR, 3 GHz < f ≤ 6Ghz | 1.3:1 | |
| connector | precision N, female | |
| DUT TX | max. DUT input power | +26 dBm |
| max. input DC level | 0 V DC | |
| nominal source impedance | 50 Ω | |
| max. VSWR, 400 MHz ≤ f <3 GHz | 1.2:1 | |
| max. VSWR, 3 GHz < f ≤ 6Ghz | 1.3:1 | |
| connector | precision N, female | |
| REF OUT IB | max. RF output power | ≥–10 dBm (PEP) |
| nominal source impedance | 50 Ω | |
| max. VSWR, 400 MHz ≤ f <3 GHz | 1.2:1 | |
| max. VSWR, 3 GHz < f ≤ 6Ghz | 1.3:1 | |
| connector | precision N, female | |
| Operating data | ||
| AC power supply and consumption | phase | single phase (P + N + PE) |
| voltage | 115 V to 230 V AC ±6 % | |
| frequency | 47 Hz to 63 Hz | |
| power consumption | max. 3.5 kVA | |
| mains connector | IEC60309-2, P + N + PE, 6 h | |
| General data | ||
| Environmental conditions | storage temperature range | 0 °C to +40 °C |
| operating temperature range | +20 °C to +26 °C | |
| operating temperature after RF calibration | ±2 °C around temperature during RFC | |
| relative humidity, non-condensing | 20 % to 80 % | |
| Electrical safety | measurement equipment | IEC 1010-1, EN 61010 part 1, VDE 0411 part 1 |
| IT equipment | IEC 950, EN 6095, VDE 0805 | |
| EMC | emission | EN 55011 group I class B, EN 55022 class B |
| immunity | EN 61326, EN 55011 | |
| Dimensions | W × H × D | approx. 600 mm × 1980 mm × 800 mm (approx. 23.6 in × 78.0 in × 31.5 in) |