R&S®TS8980IB RF ConformanceTest System

Integrated test system for LTE conformance tests

Specifications

Common data
Overall frequency range depending on specific device configuration 400 MHz to 6.0 GHz or
400 MHz to 3 GHz
Maximum DUT cable loss   3,5 dB (6 GHz)
DUT TX/RX 1 and DUT TX/RX 2 max. RF output power ≥–25 dBm RMS
  max. DUT input power +26 dBm
  max. input DC level 0 V DC
  nominal source impedance 50 Ω
  max. VSWR, 400 MHz ≤ f <3 GHz 1.2:1
  max. VSWR, 3 GHz < f ≤ 6Ghz 1.3:1
  connector precision N, female
DUT TX max. DUT input power +26 dBm
  max. input DC level 0 V DC
  nominal source impedance 50 Ω
  max. VSWR, 400 MHz ≤ f <3 GHz 1.2:1
  max. VSWR, 3 GHz < f ≤ 6Ghz 1.3:1
  connector precision N, female
REF OUT IB max. RF output power ≥–10 dBm (PEP)
  nominal source impedance 50 Ω
  max. VSWR, 400 MHz ≤ f <3 GHz 1.2:1
  max. VSWR, 3 GHz < f ≤ 6Ghz 1.3:1
  connector precision N, female
Operating data
AC power supply and consumption phase single phase (P + N + PE)
  voltage 115 V to 230 V AC ±6 %
  frequency 47 Hz to 63 Hz
  power consumption max. 3.5 kVA
  mains connector IEC60309-2, P + N + PE, 6 h
General data
Environmental conditions storage temperature range 0 °C to +40 °C
  operating temperature range +20 °C to +26 °C
  operating temperature after RF calibration ±2 °C around temperature during RFC
  relative humidity, non-condensing 20 % to 80 %
Electrical safety   measurement equipment   IEC 1010-1, EN 61010 part 1, VDE 0411 part 1
  IT equipment   IEC 950, EN 6095, VDE 0805
EMC emission EN 55011 group I class B, EN 55022 class B
  immunity EN 61326, EN 55011
Dimensions W × H × D approx. 600 mm × 1980 mm × 800 mm
(approx. 23.6 in × 78.0 in × 31.5 in)
Weight depending on specific configuration approx. 400 kg (approx. 882 lb)