R&S®ZVL6 Vector Network Analyzer

Frequency range: 9 kHz to 6 GHz
Test ports: N(f), 50 Ω

Ordering Information
Designation Type Order No.
Base Unit
Picture Vector Network Analyzer
Frequency range: 9 kHz to 6 GHz
Test ports: N(f), 50 Ω
R&S®ZVL6 1303.6509.06
Firmware Options
Spectrum Analysis for R&S®ZVL
(enabled by key code)
R&S®ZVL-K1 1306.0301.02
Distance-to-Fault Measurement
(enabled by key code)
R&S®ZVL-K2 1306.0101.02
Time Domain Analysis for R&S®ZVL R&S®ZVL-K3 1306.0201.02
Hardware Options
OCXO Reference Frequency R&S®FSL-B4 1300.6008.02
GPIB Interface R&S®FSL-B10 1300.6208.02
DC Power Supply, 12 V to 28 V R&S®FSL-B30 1300.6308.02
NiMH Battery Pack
(requires R&S®FSL-B30)
R&S®FSL-B31 1300.6408.02
Hardware Options requiring R&S®ZVL-K1
Additional Interfaces
(video out, IF out, noise source control, AUX port, connector for the R&S®NRP power sensors)
R&S®FSL-B5 1300.6108.02
Picture TV Trigger R&S®FSL-B6 1300.5901.02
Narrow Resolution Filters
10 Hz to 300 Hz
R&S®FSL-B7 1300.5601.02
Gated Sweep Function R&S®FSL-B8 1300.5701.02
RF Preamplifier
3 GHz/6 GHz
R&S®FSL-B22 1300.5953.02
Firmware Options requiring R&S®ZVL-K1
AM/FM/φM measurement demodulator R&S®FSL-K7 1301.9246.02
Transmitter measurements for Bluetooth® V2.0 and EDR R&S®FSL-K8 1301.9398.02
Power Sensor Support
(requires R&S®FSL-B5 or R&S®NRP-Z3/4)
R&S®FSL-K9 1301.9530.02
Spectrogram Measurements R&S®FSL-K14 1302.0913.02
Analog and digital cable TV measurements R&S®FSL-K20 1301.9675.02
Noise figure and gain measurements
(requires R&S®FSL-B5, and a preamplifier)
R&S®FSL-K30 1301.9817.02
3GPP FDD BTS Application Firmware R&S®FSL-K72 1302.0620.02
WLAN Application Firmware
WLAN IEEE 802.11 a/b/g/j TX Application Firmware
R&S®FSL-K91 1302.0094.02
Application Firmware
TX measurements on OFDMA signals in line with IEEE802.16-2004, IEEE802.16e-2005
R&S®FSL-K93 1302.0736.02
Supported Power Sensors
Picture Universal Power Sensor
True universal power sensor for a vast number of applications
Measurement range: -67 dBm to +23 dBm
Frequency range: 10 MHz to 8 GHz
N connector
R&S®NRP-Z11 1138.3004.02 / 1138.3004.04
Picture Universal Power Sensor
True universal power sensor for a vast number of applications
Measurement range: -67 dBm to +23 dBm
Frequency range: 10 MHz to 18 GHz
N connector
R&S®NRP-Z21 1137.6000.02
Picture Universal Power Sensor
True universal power sensor for a vast number of applications
Measurement range: -57 dBm to +33 dBm
Frequency range: 10 MHz to 18 GHz
N connector
R&S®NRP-Z22 1137.7506.02
Picture Universal Power Sensor
True universal power sensor for a vast number of applications
Measurement range: -47 dBm to +42 dBm
Frequency range: 10 MHz to 18 GHz
N connector
R&S®NRP-Z23 1137.8002.02
Picture Universal Power Sensor
True universal power sensor for a vast number of applications
Measurement range: -42 dBm to +45 dBm
Frequency range: 10 MHz to 18 GHz
N connector
R&S®NRP-Z24 1137.8502.02
Picture Thermal Power Sensor
Highly accurate continuous average power measurements
Measurement range: -30 dBm to +20 dBm
Frequency range: DC to 18 GHz
N connector
R&S®NRP-Z51 1138.0005.02
Picture Thermal Power Sensor
Highly accurate continuous average power measurements
Measurement range: -35 dBm to +20 dBm
Frequency range: DC to 40 GHz
2.92 mm connector
R&S®NRP-Z55 1138.2008.03
Picture Thermal Power Sensor
Highly accurate continuous average power measurements
Measurement range: –35 dBm to +20 dBm
Frequency range: DC to 50 GHz
2,4 mm connector
R&S®NRP-Z56 1171.8201.02
Picture Wideband Power Sensor
Peak power measurements of radar and mobile communications signals
Measurement range: -60 dBm to +20 dBm
Frequency range: 50 MHz to 18 GHz
N connector
R&S®NRP-Z81 1137.9009.02
Picture Average Power Sensor
Specially designed for EMC applications
Measurement range: -67 dBm to +23 dBm
Frequency range: 9 kHz to 6 GHz
N connector
R&S®NRP-Z91 1168.8004.02 / 1168.8004.04
Picture Wideband Power Sensor
Peak power measurements of radar and mobile communications signals
Measurement range: -60 dBm to +20 dBm
Frequency range: 50 MHz to 40 GHz
2,92 mm connector
R&S®NRP-Z85 1411.7501.02
Picture Wideband Power Sensor
Peak power measurements of radar and mobile communications signals
Measurement range: -60 dBm to +20 dBm
Frequency range: 50 MHz to 40 GHz
2,4 mm connector
R&S®NRP-Z86 1417.0109.40
Measurement Accessories - Test Cables (Economy, single Items)
N (m)/N (m), 18 GHz
61 cm (24”), 1 item
R&S®ZV-Z191 1306.4507.24
N (m)/N (m), 18 GHz
91 cm (36”), 1 item
R&S®ZV-Z191 1306.4507.36
N (m)/3.5 mm (m), 18 GHz
61 cm (24”), 1 item
R&S®ZV-Z192 1306.4513.24
N (m)/3.5 mm (m), 18 GHz
91 cm (36”), 1 item
R&S®ZV-Z192 1306.4513.36
RF-Cable; 50 Ohm
3.5mm(f) to 3.5mm(m); DC to 26.5 GHz; flexible-phasestable; 1520 mm / 60 inch; 1 piece
R&S®ZV-Z193 1306.4520.60
RF-Cable; 50 Ohm
3.5mm(f) to 3.5mm(m); DC to 26.5 GHz; flexible-phasestable; 1520 mm / 60 inch; 1 piece
R&S®ZVZ193 1306.4520.61
Calibration Accessories - Manual Calibration Kits and Components
Calibration Kit, 0 Hz to 18 GHz, Type N (7mm)
Open, Short, Match, Through, m/f each
R&S®ZV-Z270 5011.6536.02
Picture Calibration Kit, 0 Hz to 3 GHz, N, 50 Ω R&S®ZCAN 0800.8515.52
Calibration Kit, 0 Hz to 9 GHz, N(m), 50 Ω
Open, Short, Match, Through combination
R&S®ZV-Z170 1317.7683K02
Calibration Kit, 0 Hz to 9 GHz, N(f), 50 Ω
Open, Short, Match, Through combination
R&S®ZV-Z170 1317.7683K03
Calibration Kit, 0 Hz to 26 GHz, 3.5mm
Open, Short, Match, Through, m/f each
R&S®ZV-Z235 5011.6542.02
Measurement Accessories - Matching Pads
Matching Pad, 50 Ω/75 Ω,
bidirectional, 0 Hz to 1 GHz, BNC female/N male connectors, load capacity 1 W
R&S®FSH-Z38 1300.7740.02
Instrument Accessories
19“-Rack Adapter R&S®ZZA-S334 1109.4487.00
Picture Soft Carrying Bag R&S®FSL-Z3 1300.5401.00
Additional Charger Unit R&S®FSL-Z4 1300.5430.02