R&S®ZVL6 Vector Network Analyzer
Frequency range: 9 kHz to 6 GHz
Test ports: N(f), 50 Ω
Ordering Information
| Designation | Type | Order No. | |
|---|---|---|---|
| Base Unit | |||
|
|
Vector Network Analyzer Frequency range: 9 kHz to 6 GHz Test ports: N(f), 50 Ω |
|
1303.6509.06 |
| Firmware Options | |||
|
Spectrum Analysis for (enabled by key code) |
|
1306.0301.02 | |
|
Distance-to-Fault Measurement (enabled by key code) |
|
1306.0101.02 | |
|
Time Domain Analysis for |
|
1306.0201.02 | |
| Hardware Options | |||
| OCXO Reference Frequency |
|
1300.6008.02 | |
| GPIB Interface |
|
1300.6208.02 | |
| DC Power Supply, 12 V to 28 V |
|
1300.6308.02 | |
|
NiMH Battery Pack (requires |
|
1300.6408.02 | |
| Hardware Options requiring R&S®ZVL-K1 | |||
|
Additional Interfaces (video out, IF out, noise source control, AUX port, connector for the |
|
1300.6108.02 | |
|
|
TV Trigger |
|
1300.5901.02 |
|
Narrow Resolution Filters 10 Hz to 300 Hz |
|
1300.5601.02 | |
| Gated Sweep Function |
|
1300.5701.02 | |
|
RF Preamplifier 3 GHz/6 GHz |
|
1300.5953.02 | |
| Firmware Options requiring R&S®ZVL-K1 | |||
| AM/FM/φM measurement demodulator |
|
1301.9246.02 | |
| Transmitter measurements for Bluetooth® V2.0 and EDR |
|
1301.9398.02 | |
|
Power Sensor Support (requires |
|
1301.9530.02 | |
| Spectrogram Measurements |
|
1302.0913.02 | |
| Analog and digital cable TV measurements |
|
1301.9675.02 | |
|
Noise figure and gain measurements (requires |
|
1301.9817.02 | |
| 3GPP FDD BTS Application Firmware |
|
1302.0620.02 | |
|
WLAN Application Firmware WLAN IEEE 802.11 a/b/g/j TX Application Firmware |
|
1302.0094.02 | |
|
Application Firmware TX measurements on OFDMA signals in line with |
|
1302.0736.02 | |
| Supported Power Sensors | |||
|
Universal Power Sensor True universal power sensor for a vast number of applications Measurement range: -67 dBm to +23 dBm Frequency range: 10 MHz to 8 GHz N connector |
|
1138.3004.02 / 1138.3004.04 |
|
Universal Power Sensor True universal power sensor for a vast number of applications Measurement range: -67 dBm to +23 dBm Frequency range: 10 MHz to 18 GHz N connector |
|
1137.6000.02 |
|
Universal Power Sensor True universal power sensor for a vast number of applications Measurement range: -57 dBm to +33 dBm Frequency range: 10 MHz to 18 GHz N connector |
|
1137.7506.02 |
|
Universal Power Sensor True universal power sensor for a vast number of applications Measurement range: -47 dBm to +42 dBm Frequency range: 10 MHz to 18 GHz N connector |
|
1137.8002.02 |
|
Universal Power Sensor True universal power sensor for a vast number of applications Measurement range: -42 dBm to +45 dBm Frequency range: 10 MHz to 18 GHz N connector |
|
1137.8502.02 |
|
Thermal Power Sensor Highly accurate continuous average power measurements Measurement range: -30 dBm to +20 dBm Frequency range: DC to 18 GHz N connector |
|
1138.0005.02 |
|
Thermal Power Sensor Highly accurate continuous average power measurements Measurement range: -35 dBm to +20 dBm Frequency range: DC to 40 GHz 2.92 mm connector |
|
1138.2008.03 |
|
Thermal Power Sensor Highly accurate continuous average power measurements Measurement range: –35 dBm to +20 dBm Frequency range: DC to 50 GHz 2,4 mm connector |
|
1171.8201.02 |
|
Wideband Power Sensor Peak power measurements of radar and mobile communications signals Measurement range: -60 dBm to +20 dBm Frequency range: 50 MHz to 18 GHz N connector |
|
1137.9009.02 |
|
Average Power Sensor Specially designed for EMC applications Measurement range: -67 dBm to +23 dBm Frequency range: 9 kHz to 6 GHz N connector |
|
1168.8004.02 / 1168.8004.04 |
|
Wideband Power Sensor Peak power measurements of radar and mobile communications signals Measurement range: -60 dBm to +20 dBm Frequency range: 50 MHz to 40 GHz 2,92 mm connector |
|
1411.7501.02 |
|
Wideband Power Sensor Peak power measurements of radar and mobile communications signals Measurement range: -60 dBm to +20 dBm Frequency range: 50 MHz to 40 GHz 2,4 mm connector |
|
1417.0109.40 |
| Measurement Accessories - Test Cables (Economy, single Items) | |||
|
N (m)/N (m), 18 GHz 61 cm (24”), 1 item |
|
1306.4507.24 | |
|
N (m)/N (m), 18 GHz 91 cm (36”), 1 item |
|
1306.4507.36 | |
|
N (m)/3.5 mm (m), 18 GHz 61 cm (24”), 1 item |
|
1306.4513.24 | |
|
N (m)/3.5 mm (m), 18 GHz 91 cm (36”), 1 item |
|
1306.4513.36 | |
|
RF-Cable; 50 Ohm 3.5mm(f) to 3.5mm(m); DC to 26.5 GHz; flexible-phasestable; 1520 mm / 60 inch; 1 piece |
|
1306.4520.60 | |
|
RF-Cable; 50 Ohm 3.5mm(f) to 3.5mm(m); DC to 26.5 GHz; flexible-phasestable; 1520 mm / 60 inch; 1 piece |
|
1306.4520.61 | |
| Calibration Accessories - Manual Calibration Kits and Components | |||
|
Calibration Kit, 0 Hz to 18 GHz, Type N (7mm) Open, Short, Match, Through, m/f each |
|
5011.6536.02 | |
|
|
Calibration Kit, 0 Hz to 3 GHz, N, 50 Ω |
|
0800.8515.52 |
|
Calibration Kit, 0 Hz to 9 GHz, N(m), 50 Ω Open, Short, Match, Through combination |
|
1317.7683K02 | |
|
Calibration Kit, 0 Hz to 9 GHz, N(f), 50 Ω Open, Short, Match, Through combination |
|
1317.7683K03 | |
|
Calibration Kit, 0 Hz to 26 GHz, 3.5mm Open, Short, Match, Through, m/f each |
|
5011.6542.02 | |
| Measurement Accessories - Matching Pads | |||
|
Matching Pad, 50 Ω/75 Ω, bidirectional, 0 Hz to 1 GHz, BNC female/N male connectors, load capacity 1 W |
|
1300.7740.02 | |
| Instrument Accessories | |||
| 19“-Rack Adapter |
|
1109.4487.00 | |
|
Soft Carrying Bag |
|
1300.5401.00 |
| Additional Charger Unit |
|
1300.5430.02 | |