R&S®FS-K15 VOR/ILS Measurement Demodulator

for R&S®FSMR/R&S®FSU/R&S®FSQ - Analysis for VOR and ILS signals

Key Facts

Frequency range: 107 MHz to 120 MHz and 319 MHz to 341 MHz specified; can be used in the frequency range of the base unit
Level range: -60 dBm to +30 dBm
Measurement functions VOR: VOR phase, modulation depth and frequency for 30 Hz, subcarrier, identifier, 9.96 kHz subcarrier deviation, modulation depth and frequency of the subcarrier, THD; phase between 90 Hz and 150 Hz signal
VOR phase: 0° to 360°, 0.1° resolution
Measurement uncertainty VOR phase: 0.003°
Measurement functions ILS: DDM, SDM, modulation depth and frequency at 90 Hz/150 Hz/identifier, THD
Measurement range DDM: 0 DDM to 0.4 DDM
Measurement uncertainty DDM: 0.0002 DDM + 1 % of reading