Specifications

Frequency
Frequency range with the R&S®SGS-B106 option 1 MHz to 6 GHz
  with the R&S®SGS-B106 and R&S®SGS-B112 options 1 MHz to 12.75 GHz
  with the R&S®SGS-B106V option 80 MHz to 6 GHz (I/Q mode)
1 MHz to 6 GHz (CW mode)
Setting time with PCIe remote control < 500 μs
Input frequency for external reference   10 MHz, 100 MHz, 1000 MHz
Level
Specified level range   –10 dBm to +15 dBm (PEP) 1)
  with the R&S®SGS-B26 option –120 dBm to +15 dBm (PEP) 1)
Level error Setting Characteristic: AUTO; temperature range from +18 °C to +33 °C
     1 MHz ≤ f ≤ 3 GHz < 0.5 dB
     3 GHz < f ≤ 12.75 GHz < 0.9 dB
Output impedance VSWR in 50 Ω system in full frequency range,
Setting Characteristic: AUTO
< 2.0
  in full frequency range,
with the R&S®SGS-B26 option
< 1.8
Setting time with PCIe remote control,
Setting Characteristic: AUTO
< 500 μs
Spectral purity
Harmonics level ≤ 8 dBm, CW, I/Q wideband OFF < –30 dBc
Nonharmonics level > –10 dBm 2), offset > 10 kHz from carrier, f ≤ 1.5 GHz < –76 dBc
Subharmonics level > –10 dBm 2), f ≤ 3GHz < –76dBc
Wideband noise 1 MHz ≤ f ≤ 6 GHz and 10 MHz carrier offset, 6 GHz < f ≤ 12.75 GHz and 30 MHz carrier offset, AUTO mode, level > 5 dBm, 1 Hz measurement bandwidth, CW < –145 dBc
SSB phase noise 20 kHz carrier offset, 1 Hz measurement bandwidth
     f = 1 GHz < –126 dBc, –130 dBc (typ.)
     f = 10 GHz < –106 dBc, –110 dBc (typ.)
I/Q modulation
I/Q modulator bandwidth (RF) 100 MHz < f ≤ 2.5 GHz, I/Q wideband 40 % of carrier frequency
  2.5 GHz < f ≤ 6 GHz, I/Q wideband 1 GHz
Error vector measured with 16QAM, filter root cosine α = 0.5, 10 kHz symbol rate
     f > 80 MHz, RMS < (0.4 % + 0.2 % × f/GHz)
ACLR WCDMA 3GPP FDD, TM 1/64 > 67 dB, 69.5 dB (meas.)
Baseband bypass mode
Frequency range   1 MHz ≤ f ≤ 80 MHz
Specified level range   –5 dBm to +15 dBm
  with the R&S®SGS-B26 option –120 dBm to +15 dBm
Remote control using Rohde & Schwarz instrument driver PCIe (single lane)
  using SCPI 1999.5 or compatible command sets Ethernet (TCP/IP) 10/100/1000BaseT
  using SCPI 1999.5 or compatible command sets USB 2.0
General data
Power consumption   70 W (meas.)
Dimensions W × H × D 250 mm × 52.5 mm × 401 mm
(9.84 in × 2.07 in × 15.79 in)
1 HU, ½ 19" rack width
Weight when fully equipped 4.0 kg (8.82 lb)

1) PEP = peak envelope power.
2) > 0 dBm for instruments without the R&S®SGS-B26 electronic step attenuator.