Specifications

  R&S®FS-Z60 R&S®FS-Z75 R&S®FS-Z90 R&S®ZS-Z110
Frequency range 40 GHz to 60 GHz 50 GHz to 75 GHz 60 GHz to 90 GHz 75 GHz to 100 GHz
Level
Maximum CW RF input level
(LO level < max. permissible LO level)
+16 dBm +16 dBm +16 dBm 0 dBm
1 dB compression +4 dBm nominal +6 dBm nominal +6 dBm nominal -3 dBm nominal
Conversion loss with R&S®FSP, R&S®FSU, R&S®FSV or R&S®FSUP, LO level set between +15.5 dBm and +17 dBm
4th LO harmonic selected, 40 GHz ≤ fRF ≤ 60 GHz
6th LO harmonic selected, 40 GHz ≤ fRF ≤ 60 GHz
≤ 25 dB, typ. 23 dB
≤ 30 dB, typ. 28 dB
- - -
6th LO harmonic selected, 50 GHz ≤ fRF ≤ 75 GHz - ≤ 34 dB, typ. 25 dB - -
6th LO harmonic selected, 60 GHz ≤ fRF ≤ 90 GHz - - ≤ 37.5 dB, typ. 34 dB -
8th LO harmonic selected, 75 GHz ≤ fRF < 95 GHz
8th LO harmonic selected, 95 GHz ≤ fRF ≤ 110 GHz
10th LO harmonic selected, 85 GHz ≤ fRF ≤ 110 GHz
- - - ≤ 25 dB, typ. 23 dB
≤ 33 dB, typ. 31 dB
≤ 35 dB, typ. 33 dB
Displayed average noise level
RBW = 1 kHz, VBW = 3 kHz, zero span, sweep time 50 ms, sample detector, log. scaling, trace average, sweep count = 20, mean marker, normalized to 1 Hz RBW ≤ –140 dBm
typ. ≤ –145 dBm
≤ –137 dBm
typ. ≤ –128 dBm
≤ –124 dBm
typ. ≤ –128 dBm
≤ –135 dBm
typ. ≤ –140 dBm
Measurement uncertainty with the R&S®FSP, R&S®FSU, R&S®FSV or R&S®FSUP, LO level set between +15.5 dBm and +17 dBm
Level uncertainty at calibrated frequency points 95 % confidence level < 3.0 dB (+25°C)
< 4.5 dB (+5°C to +40°C)
Frequency response < 5.0 dB, within any
5 GHz band
< 5.0 dB, within any
5 GHz band
< 5.0 dB, within any
5 GHz band
< 6.0 dB, within any
1 GHz band
Temperature drift (max.)
+5°C to +40°C
–20°C to +60°C
 
< 1.5 dB
< 2.5 dB
RF input
Connector WR19, UG-383/
U-M flange (modified)
WR15, UG-385/
U flange
WR12, UG-387/
U flange
WR10, UG-387/
U-M flange
VSWR < 3.5 : 1, typ. 2.5 : 1 < 3.5 : 1, typ. 2.2 : 1 < 3.6 : 1, typ. 2.5 : 1 < 1.5 : 1, typ. 1.4 : 1
LO input
Connector SMA connector SMA connector SMA connector SMA connector
Frequency range 9.9 GHz to 14.9 GHz 8.3 GHz to 12.4 GHz 7.4 GHz to 14.9 GHz 9.3 GHz to 13.7 GHz
Maximum rated LO level
(RF input level < max. permissible CW RF input level)
+19 dBm +19 dBm +19 dBm +18 dBm
IF output
Connector -1) -1) -1) SMA connector
Frequency range 400 MHz to 800 MHz nominal
General data
Operating temperature range +5°C to +40°C
Permissible temperature range –20°C to +60°C
Storage temperature range –40°C to +70°C
Climatic loading +40°C at 95% relative humidity (DIN EN 60068-2-30: 2000-02)
Dimensions in mm (W × H × D)
Dimensions in inches (W × H × D)
28.6 × 33.8 × 63.5

1.13 × 1.33 × 2.5
20.0 × 29.5 × 60.0

0.79 × 1.16 × 2.36
20.0 × 29.5 × 60.0

0.79 × 1.16 × 2.36
27.1 × 24.1 × 95.0

1.07 × 0.95 × 3.74
Weight 170 g
0.37 lb
150 g
0.33 lb
150 g
0.33 lb
180 g
0.4 lb
Accessories supplied
Operating manual, disk with calibrated conversion loss data, carrying case

1) LO input and IF output use the same connector.