R&S®FS-Z60/-Z75/-Z90/-Z110 Harmonic Mixers
for the R&S®FSP/FSU/ FSQ/FSUP/FSV
Specifications
| Frequency range | 40 GHz to 60 GHz | 50 GHz to 75 GHz | 60 GHz to 90 GHz | 75 GHz to 100 GHz |
| Level | ||||
| Maximum CW RF input level (LO level < max. permissible LO level) |
+16 dBm | +16 dBm | +16 dBm | 0 dBm |
| 1 dB compression | +4 dBm nominal | +6 dBm nominal | +6 dBm nominal | -3 dBm nominal |
| Conversion loss with |
||||
| 4th LO harmonic selected, 6th LO harmonic selected, |
≤ 25 dB, typ. 23 dB ≤ 30 dB, typ. 28 dB |
- | - | - |
| 6th LO harmonic selected, |
- | ≤ 34 dB, typ. 25 dB | - | - |
| 6th LO harmonic selected, |
- | - | ≤ 37.5 dB, typ. 34 dB | - |
| 8th LO harmonic selected, 8th LO harmonic selected, 10th LO harmonic selected, |
- | - | - | ≤ 25 dB, typ. 23 dB ≤ 33 dB, typ. 31 dB ≤ 35 dB, typ. 33 dB |
| Displayed average noise level | ||||
| RBW = 1 kHz, VBW = 3 kHz, zero span, sweep time 50 ms, sample detector, log. scaling, trace average, sweep count = 20, mean marker, normalized to 1 Hz RBW | ≤ –140 dBm typ. ≤ –145 dBm |
≤ –137 dBm typ. ≤ –128 dBm |
≤ –124 dBm typ. ≤ –128 dBm |
≤ –135 dBm typ. ≤ –140 dBm |
| Measurement uncertainty with the |
||||
| Level uncertainty at calibrated frequency points 95 % confidence level | < 3.0 dB (+25°C) < 4.5 dB (+5°C to +40°C) |
|||
| Frequency response | < 5.0 dB, within any 5 GHz band |
< 5.0 dB, within any 5 GHz band |
< 5.0 dB, within any 5 GHz band |
< 6.0 dB, within any 1 GHz band |
| Temperature drift (max.) +5°C to +40°C –20°C to +60°C |
< 1.5 dB < 2.5 dB |
|||
| RF input | ||||
| Connector | WR19, UG-383/ U-M flange (modified) |
WR15, UG-385/ U flange |
WR12, UG-387/ U flange |
WR10, UG-387/ U-M flange |
| VSWR | ||||
| LO input | ||||
| Connector | SMA connector | SMA connector | SMA connector | SMA connector |
| Frequency range | 9.9 GHz to 14.9 GHz | 8.3 GHz to 12.4 GHz | 7.4 GHz to 14.9 GHz | 9.3 GHz to 13.7 GHz |
| Maximum rated LO level (RF input level < max. permissible CW RF input level) |
+19 dBm | +19 dBm | +19 dBm | +18 dBm |
| IF output | ||||
| Connector | -1) | -1) | -1) | SMA connector |
| Frequency range | 400 MHz to 800 MHz nominal | |||
| General data | ||||
| Operating temperature range | +5°C to +40°C | |||
| Permissible temperature range | –20°C to +60°C | |||
| Storage temperature range | –40°C to +70°C | |||
| Climatic loading | +40°C at 95% relative humidity (DIN EN 60068-2-30: 2000-02) | |||
| Dimensions in mm (W × H × D) Dimensions in inches (W × H × D) |
28.6 × 33.8 × 63.5 1.13 × 1.33 × 2.5 |
20.0 × 29.5 × 60.0 0.79 × 1.16 × 2.36 |
20.0 × 29.5 × 60.0 0.79 × 1.16 × 2.36 |
27.1 × 24.1 × 95.0 1.07 × 0.95 × 3.74 |
| Weight | 170 g 0.37 lb |
150 g 0.33 lb |
150 g 0.33 lb |
180 g 0.4 lb |
| Accessories supplied | ||||
| Operating manual, disk with calibrated conversion loss data, carrying case | ||||
1) LO input and IF output use the same connector.