Features

Measurement functions

  • Noise marker for determining the noise power referenced to 1 Hz measurement bandwidth
  • Frequency counter with 0.1 Hz resolution
  • Limit line monitoring (pass/fail function) for indicating whether the DUT complies with defined limits
  • Modulation depth measurement of AM-modulated signals
  • Measurement of harmonics and total harmonic distortion
  • AM/FM audio demodulator (audio via built-in loudspeaker or via headphones)
  • Scalar transmission measurement for fast and simple determination of the transmission characteristics of DUTs such as cables, filters or amplifiers (available for the R&S®FSC models .13 and .16 with tracking generator)
  • Location of EMC problems on printed boards using the R&S®HZ-15 near-field probe set for emission measurements from 30 MHz to 3 GHz
  • Field-strength measurements taking into account the specific antenna factors of the connected antenna, the field strength being displayed directly in dBμV/m
  • Power measurement on pulsed signals in the time domain with predefined settings for the GSM and EDGE mobile radio standards
  • Channel power measurement in a definable transmission channel with predefined settings for 3GPP WCDMA, cdmaOne, CDMA2000® and LTE mobile communications standards
  • Measurement of occupied bandwidth (OBW)
  • Adjacent channel power, absolute or referenced to the TX carrier for up to 12 channels and 12 adjacent channels
  • Gated sweep for displaying the modulation spectrum of burst signals such as GSM or WLAN
  • Measurement of spurious emissions